Hybrid Inverter 15-20kw

Hybrid Inverter 15-20kw
Product Introduction:
The Hybrid Inverter 15-20kw integrates solar PV input, battery storage management, and grid interaction in a single system. It supports both grid-tied and off-grid operation for residential and small commercial energy storage applications.
Send Inquiry
Description
Technical Parameters

Product Overview

 

The Hybrid Inverter 15-20kw integrates solar PV input, battery storage management, and grid interaction in a single system. It supports both grid-tied and off-grid operation for residential and small commercial energy storage applications.

 

product-204-165product-184-179

 

Specifications

 

Specifications are based on standard three-phase residential and small commercial energy storage system configurations.

 

Modell

SUN-14K-SG05LP3

SUN-15K-SG05LP3

SUN-16K-SG05LP3

SUN-18K-SG05LP3

SUN-20K-SG05LP3

-EU-SM2

-EU-SM2

-EU-SM2

-EU-SM2

-EU-SM2

Battery Input Data

Battery Type

Lead-acid or Lithium-ion

Battery Voltage Range (V)

40-60

Max. Charging Current (A)

260

280

300

330

350

Max. Discharging Current (A)

260

280

300

330

350

Charging Strategy forLi-ion Battery

Self-adaption to BMS

Number of Battery Input

1

PV String Input Data

Max. PV Access Power (W)

28000

30000

32000

36000

40000

Max. DC Input Power (W)

22400

24000

25600

28800

32000

Max. DC Input Voltage (V)

800

Start-up Voltage (V)

160

MPPT Voltage Range (V)

160-650

Rated DC Input Voltage (V)

550

Max. Operating PV Input Current (A)

36+36

Max. Input Short-Circuit Current (A)

54+54

No.of MPPT Trackers/

2/2+2

No.of String PerMPPT Tracker

AC Input/Output Data

 

Rated AC Input/Output Active Power (W)

14000

15000

16000

18000

20000

Max. AC Input/Output Apparent Power (VA)

15400

16500

17600

19800

22000

Rated AC Input/Output Current (A)

21.3/20.3

22.8/21.8

24.3/23.2

27.3/26.1

30.4/29

Max. AC Input/Output Current (A)

23.4/22.4

25/24

26.7/25.6

30/28.7

33.4/31.9

Max. Continuous AC Passthrough (grid to load) (A)

70

Peak Power (off-grid) (W)

2 times of rated power, 10s

Power Factor Adjustment Range

0.8 leading to 0.8 lagging

Rated Input/Output Voltage/Range (V)

220/380V, 230/400V 0.85Un-1.1Un

Rated Input/Output Grid Frequency/Range(Hz)

50/45-55, 60/55-65

Grid Connection Form

3L+N+PE

Total Current Harmonic Distortion THDi

<3% (of nominal power)

DC Component of Grid

<0.5% In

Efficiency

 

Max. Efficiency

97.60%

Euro Efficiency

97.00%

MPPTEfficiency

>99%

Equipment Protection

 

Integrated

DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,

AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,

Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),

Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,

DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level

Surge Protection Level

TYPE II(DC),TYPE II(AC)

Interface

 

Communication Interface

RS485/RS232/CAN

Monitor Mode

GPRS/WIFI/Bluetooth/4G/LAN(optional)

General Data

 

Operating Temperature Range (℃)

-40 to +60℃, >45℃ Derating

Permissible Ambient Humidity

0-100%

Permissible Altitude

3000m

Noise

≤60

Ingress Protection(IP) Rating

IP 65

Inverter Topology

Non-Isolated

Over Voltage Category

OVC II(DC), OVC III(AC)

Cabinet Size (WxHxD mm)

456×750×268.5 (Excluding Connectors and Brackets)

Weight (kg)

51.9

Type of Cooling

Intelligent Air Cooling

Warranty

5 Years/10 Years

the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

Grid Regulation

IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,

OVE-Richtlinie R25, G99,VDE-AR-N 4105

Safety / EMC Standard

IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

 

Core Advantages

 

Supports up to 40kW PV input with dual MPPT for flexible array configuration and improved energy yield.

 

Compatible with lithium and lead-acid batteries (40–60V) with CAN/RS485 BMS communication.

 

Supports 2× overload for 10 seconds for motor start-up loads.

 

Compatible with 220/380V and 230/400V grids and major international standards.

 

Applications

 

Residential solar + storage systems (villas, apartments, multi-family houses)

 

Small commercial energy storage systems (shops, offices, workshops)

 

Backup power systems for critical loads

 

Hybrid PV + battery systems for peak shaving and tariff optimization

 

Off-grid and weak-grid energy applications

 

Grid & System Control Capability

 

The system supports automatic synchronization with the utility grid and maintains stable operation under voltage and frequency fluctuations.

 

It is designed to comply with international grid connection requirements including IEC and EN standards.

 

Factory Quality Control

 

<0.1% DOA Rate: Every hybrid inverter undergoes a mandatory 4-hour automated simulation test under 100% full thermal and load conditions before final packing.

 

BMS Interoperability Lab: Production lines utilize automated battery simulation rigs to guarantee firmware communication compatibility before shipping.

 

FAQ

 

Q: Does it support both on-grid and off-grid operation?

A: Yes. It supports hybrid operation with automatic switching. The system triggers a millisecond-level transfer to backup mode during utility grid failures.

Q: Is lithium battery supported?

A: Yes. It supports lithium and lead-acid batteries with native CAN/RS485 BMS communication. The internal firmware syncs with mainstream brands automatically.

Q: Can it be expanded in larger systems?

A: Yes. Parallel operation is supported. Up to 16 units can be paralleled in both on-grid and off-grid configurations for system scaling.

Q: Is it suitable for motor loads?

A: Yes. The inverter handles heavy inductive motor loads, supporting 2× rated peak surge power for up to 10 seconds.

Q: How are warranty claims handled for wholesale buyers?

A: We offer a replacement-based warranty. Upon remote verification of data logs or video evidence, free replacement parts or new units are dispatched with your next container shipment.

 

Hot Tags: hybrid inverter 15-20kw, China hybrid inverter 15-20kw manufacturers, suppliers, factory

Modell SUN-14K-SG05LP3 SUN-15K-SG05LP3 SUN-16K-SG05LP3 SUN-18K-SG05LP3 SUN-20K-SG05LP3
-EU-SM2 -EU-SM2 -EU-SM2 -EU-SM2 -EU-SM2
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging Current (A) 260 280 300 330 350
Max. Discharging Current (A) 260 280 300 330 350
Charging Strategy forLi-ion Battery Self-adaption to BMS
Number of Battery Input 1
PV String Input Data
Max. PV Access Power (W) 28000 30000 32000 36000 40000
Max. DC Input Power (W) 22400 24000 25600 28800 32000
Max. DC Input Voltage (V) 800
Start-up Voltage (V) 160
MPPT Voltage Range (V) 160-650
Rated DC Input Voltage (V) 550
Max. Operating PV Input Current (A) 36+36
Max. Input Short-Circuit Current (A) 54+54
No.of MPPT Trackers/ 2/2+2
No.of String PerMPPT Tracker
AC Input/Output Data  
Rated AC Input/Output Active Power (W) 14000 15000 16000 18000 20000
Max. AC Input/Output Apparent Power (VA) 15400 16500 17600 19800 22000
Rated AC Input/Output Current (A) 21.3/20.3 22.8/21.8 24.3/23.2 27.3/26.1 30.4/29
Max. AC Input/Output Current (A) 23.4/22.4 25/24 26.7/25.6 30/28.7 33.4/31.9
Max. Continuous AC Passthrough (grid to load) (A) 70
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage/Range (V) 220/380V, 230/400V 0.85Un-1.1Un
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Grid Connection Form 3L+N+PE
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Component of Grid <0.5% In
Efficiency  
Max. Efficiency 97.60%
Euro Efficiency 97.00%
MPPTEfficiency >99%
Equipment Protection  
Integrated DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,
DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC),TYPE II(AC)
Interface  
Communication Interface RS485/RS232/CAN
Monitor Mode GPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data  
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 3000m
Noise ≤60
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 456×750×268.5 (Excluding Connectors and Brackets)
Weight (kg) 51.9
Type of Cooling Intelligent Air Cooling
Warranty 5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Grid Regulation IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99,VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Send Inquiry