Product Overview
The Hybrid Inverter 15-20kw integrates solar PV input, battery storage management, and grid interaction in a single system. It supports both grid-tied and off-grid operation for residential and small commercial energy storage applications.


Specifications
Specifications are based on standard three-phase residential and small commercial energy storage system configurations.
|
Modell |
SUN-14K-SG05LP3 |
SUN-15K-SG05LP3 |
SUN-16K-SG05LP3 |
SUN-18K-SG05LP3 |
SUN-20K-SG05LP3 |
|
-EU-SM2 |
-EU-SM2 |
-EU-SM2 |
-EU-SM2 |
-EU-SM2 |
|
|
Battery Input Data |
|||||
|
Battery Type |
Lead-acid or Lithium-ion |
||||
|
Battery Voltage Range (V) |
40-60 |
||||
|
Max. Charging Current (A) |
260 |
280 |
300 |
330 |
350 |
|
Max. Discharging Current (A) |
260 |
280 |
300 |
330 |
350 |
|
Charging Strategy forLi-ion Battery |
Self-adaption to BMS |
||||
|
Number of Battery Input |
1 |
||||
|
PV String Input Data |
|||||
|
Max. PV Access Power (W) |
28000 |
30000 |
32000 |
36000 |
40000 |
|
Max. DC Input Power (W) |
22400 |
24000 |
25600 |
28800 |
32000 |
|
Max. DC Input Voltage (V) |
800 |
||||
|
Start-up Voltage (V) |
160 |
||||
|
MPPT Voltage Range (V) |
160-650 |
||||
|
Rated DC Input Voltage (V) |
550 |
||||
|
Max. Operating PV Input Current (A) |
36+36 |
||||
|
Max. Input Short-Circuit Current (A) |
54+54 |
||||
|
No.of MPPT Trackers/ |
2/2+2 |
||||
|
No.of String PerMPPT Tracker |
|||||
|
AC Input/Output Data |
|||||
|
Rated AC Input/Output Active Power (W) |
14000 |
15000 |
16000 |
18000 |
20000 |
|
Max. AC Input/Output Apparent Power (VA) |
15400 |
16500 |
17600 |
19800 |
22000 |
|
Rated AC Input/Output Current (A) |
21.3/20.3 |
22.8/21.8 |
24.3/23.2 |
27.3/26.1 |
30.4/29 |
|
Max. AC Input/Output Current (A) |
23.4/22.4 |
25/24 |
26.7/25.6 |
30/28.7 |
33.4/31.9 |
|
Max. Continuous AC Passthrough (grid to load) (A) |
70 |
||||
|
Peak Power (off-grid) (W) |
2 times of rated power, 10s |
||||
|
Power Factor Adjustment Range |
0.8 leading to 0.8 lagging |
||||
|
Rated Input/Output Voltage/Range (V) |
220/380V, 230/400V 0.85Un-1.1Un |
||||
|
Rated Input/Output Grid Frequency/Range(Hz) |
50/45-55, 60/55-65 |
||||
|
Grid Connection Form |
3L+N+PE |
||||
|
Total Current Harmonic Distortion THDi |
<3% (of nominal power) |
||||
|
DC Component of Grid |
<0.5% In |
||||
|
Efficiency |
|||||
|
Max. Efficiency |
97.60% |
||||
|
Euro Efficiency |
97.00% |
||||
|
MPPTEfficiency |
>99% |
||||
|
Equipment Protection |
|||||
|
Integrated |
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, |
||||
|
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, |
|||||
|
Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), |
|||||
|
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, |
|||||
|
DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level |
|||||
|
Surge Protection Level |
TYPE II(DC),TYPE II(AC) |
||||
|
Interface |
|||||
|
Communication Interface |
RS485/RS232/CAN |
||||
|
Monitor Mode |
GPRS/WIFI/Bluetooth/4G/LAN(optional) |
||||
|
General Data |
|||||
|
Operating Temperature Range (℃) |
-40 to +60℃, >45℃ Derating |
||||
|
Permissible Ambient Humidity |
0-100% |
||||
|
Permissible Altitude |
3000m |
||||
|
Noise |
≤60 |
||||
|
Ingress Protection(IP) Rating |
IP 65 |
||||
|
Inverter Topology |
Non-Isolated |
||||
|
Over Voltage Category |
OVC II(DC), OVC III(AC) |
||||
|
Cabinet Size (WxHxD mm) |
456×750×268.5 (Excluding Connectors and Brackets) |
||||
|
Weight (kg) |
51.9 |
||||
|
Type of Cooling |
Intelligent Air Cooling |
||||
|
Warranty |
5 Years/10 Years |
||||
|
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
|||||
|
Grid Regulation |
IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, |
||||
|
OVE-Richtlinie R25, G99,VDE-AR-N 4105 |
|||||
|
Safety / EMC Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
||||
Core Advantages
Supports up to 40kW PV input with dual MPPT for flexible array configuration and improved energy yield.
Compatible with lithium and lead-acid batteries (40–60V) with CAN/RS485 BMS communication.
Supports 2× overload for 10 seconds for motor start-up loads.
Compatible with 220/380V and 230/400V grids and major international standards.
Applications
Residential solar + storage systems (villas, apartments, multi-family houses)
Small commercial energy storage systems (shops, offices, workshops)
Backup power systems for critical loads
Hybrid PV + battery systems for peak shaving and tariff optimization
Off-grid and weak-grid energy applications
Grid & System Control Capability
The system supports automatic synchronization with the utility grid and maintains stable operation under voltage and frequency fluctuations.
It is designed to comply with international grid connection requirements including IEC and EN standards.
Factory Quality Control
<0.1% DOA Rate: Every hybrid inverter undergoes a mandatory 4-hour automated simulation test under 100% full thermal and load conditions before final packing.
BMS Interoperability Lab: Production lines utilize automated battery simulation rigs to guarantee firmware communication compatibility before shipping.
FAQ
Hot Tags: hybrid inverter 15-20kw, China hybrid inverter 15-20kw manufacturers, suppliers, factory
| Modell | SUN-14K-SG05LP3 | SUN-15K-SG05LP3 | SUN-16K-SG05LP3 | SUN-18K-SG05LP3 | SUN-20K-SG05LP3 |
| -EU-SM2 | -EU-SM2 | -EU-SM2 | -EU-SM2 | -EU-SM2 | |
| Battery Input Data | |||||
| Battery Type | Lead-acid or Lithium-ion | ||||
| Battery Voltage Range (V) | 40-60 | ||||
| Max. Charging Current (A) | 260 | 280 | 300 | 330 | 350 |
| Max. Discharging Current (A) | 260 | 280 | 300 | 330 | 350 |
| Charging Strategy forLi-ion Battery | Self-adaption to BMS | ||||
| Number of Battery Input | 1 | ||||
| PV String Input Data | |||||
| Max. PV Access Power (W) | 28000 | 30000 | 32000 | 36000 | 40000 |
| Max. DC Input Power (W) | 22400 | 24000 | 25600 | 28800 | 32000 |
| Max. DC Input Voltage (V) | 800 | ||||
| Start-up Voltage (V) | 160 | ||||
| MPPT Voltage Range (V) | 160-650 | ||||
| Rated DC Input Voltage (V) | 550 | ||||
| Max. Operating PV Input Current (A) | 36+36 | ||||
| Max. Input Short-Circuit Current (A) | 54+54 | ||||
| No.of MPPT Trackers/ | 2/2+2 | ||||
| No.of String PerMPPT Tracker | |||||
| AC Input/Output Data | |||||
| Rated AC Input/Output Active Power (W) | 14000 | 15000 | 16000 | 18000 | 20000 |
| Max. AC Input/Output Apparent Power (VA) | 15400 | 16500 | 17600 | 19800 | 22000 |
| Rated AC Input/Output Current (A) | 21.3/20.3 | 22.8/21.8 | 24.3/23.2 | 27.3/26.1 | 30.4/29 |
| Max. AC Input/Output Current (A) | 23.4/22.4 | 25/24 | 26.7/25.6 | 30/28.7 | 33.4/31.9 |
| Max. Continuous AC Passthrough (grid to load) (A) | 70 | ||||
| Peak Power (off-grid) (W) | 2 times of rated power, 10s | ||||
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | ||||
| Rated Input/Output Voltage/Range (V) | 220/380V, 230/400V 0.85Un-1.1Un | ||||
| Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | ||||
| Grid Connection Form | 3L+N+PE | ||||
| Total Current Harmonic Distortion THDi | <3% (of nominal power) | ||||
| DC Component of Grid | <0.5% In | ||||
| Efficiency | |||||
| Max. Efficiency | 97.60% | ||||
| Euro Efficiency | 97.00% | ||||
| MPPTEfficiency | >99% | ||||
| Equipment Protection | |||||
| Integrated | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, | ||||
| AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, | |||||
| Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), | |||||
| Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, | |||||
| DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level | |||||
| Surge Protection Level | TYPE II(DC),TYPE II(AC) | ||||
| Interface | |||||
| Communication Interface | RS485/RS232/CAN | ||||
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN(optional) | ||||
| General Data | |||||
| Operating Temperature Range (℃) | -40 to +60℃, >45℃ Derating | ||||
| Permissible Ambient Humidity | 0-100% | ||||
| Permissible Altitude | 3000m | ||||
| Noise | ≤60 | ||||
| Ingress Protection(IP) Rating | IP 65 | ||||
| Inverter Topology | Non-Isolated | ||||
| Over Voltage Category | OVC II(DC), OVC III(AC) | ||||
| Cabinet Size (WxHxD mm) | 456×750×268.5 (Excluding Connectors and Brackets) | ||||
| Weight (kg) | 51.9 | ||||
| Type of Cooling | Intelligent Air Cooling | ||||
| Warranty | 5 Years/10 Years | ||||
| the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | |||||
| Grid Regulation | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, | ||||
| OVE-Richtlinie R25, G99,VDE-AR-N 4105 | |||||
| Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | ||||