Product Overview
The 12KW Solar Hybrid Inverter is designed for residential and small commercial energy storage systems, combining PV input, battery management, and grid interaction in one unit for stable long-term operation under different grid conditions.
It is engineered for continuous daily operation in real-world installations, not only laboratory conditions.
Specifications
|
Model |
SUN-7.6K-SG02LP1-EU-AM2 |
SUN-8K-SG02LP1-EU-AM2 |
SUN-10K-SG02LP1-EU-AM3 |
SUN-12K-SG02LP1-EU-AM3 |
|
Battery Input Data |
||||
|
Battery Type |
Lead-acid or Lithium-ion |
|||
|
Battery Voltage Range(V) |
40-60 |
|||
|
Max.Charging Current(A) |
190 |
190 |
220 |
250 |
|
Max.Discharging Current(A) |
190 |
190 |
220 |
250 |
|
Charging Strategy for Li-ion Battery |
||||
|
Number of battery input |
1 |
|||
|
PV String Input Data |
||||
|
Max. PV Access Power (W) |
15200 |
16000 |
20000 |
24000 |
|
Max DC Input Power(W) |
12160 |
12800 |
16000 |
19200 |
|
Max DC Input Voltage(V) |
500 |
|||
|
Start-up Voltage(V) |
125 |
|||
|
MPPT Voltage Range(V) |
150-425 |
|||
|
Rated DC Input Voltage(V) |
370 |
|||
|
Max. Operating PV Input Current (A) |
26+26 |
26+26+26 |
||
|
Max. Input Short-Circuit Current (A) |
44+44 |
44+44+44 |
||
|
No.of MPP Trackers/No.of String Per MPP Tracker |
2/2+2 |
3/2+2+2 |
||
|
AC Input/Output Data |
||||
|
Rated AC Input/Output Active Power(W) |
7600 |
8000 |
10000 |
12000 |
|
Max AC Input/Output Apparent Power (VA) |
8360 |
8800 |
11000 |
13200 |
|
Peak Power (off-grid)(W) |
200% Rated Power (10s Peak Surge) |
|||
|
Rated AC Input/Output Current(A) |
34.6/33.1 |
36.4/34.8 |
45.5/43.5 |
54.6/52.2 |
|
Max AC Input/Output Current(A) |
34.6/33.1 |
36.4/34.8 |
45.5/43.5 |
54.6/52.2 |
|
Max Continuous AC Passthrough (grid to load)(A) |
50 |
60 |
||
|
Power Factor Adjustment Range |
0.8 leading to 0.8 lagging |
|||
|
Rated Input/Output Voltage/Range (V) |
220/230 0.85Un-1.1Un |
|||
|
Rated Input/Output Grid Frequency/Range(Hz) |
50/45-55, 60/55-65 |
|||
|
Grid Connection Form |
L+N+PE |
|||
|
Total Current Harmonic Distortion THDi |
<3% (of nominal power) |
|||
|
DC Injection Current |
<0.5%ln |
|||
|
Efficiency |
||||
|
Max Efficiency |
97.60% |
|||
|
Euro Efficiency |
96.50% |
|||
|
MPPT Efficiency |
>99% |
|||
|
Equipment Protection |
||||
|
Integrated |
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, |
|||
|
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, |
||||
|
Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), |
||||
|
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, |
||||
|
DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level |
||||
|
Surge Protection Level |
TYPE II(DC),TYPE II(AC) |
|||
|
Interface |
||||
|
Communication Interface |
RS485/RS232/CAN |
|||
|
Monitor Mode |
GPRS/WIFI/Bluetooth/4G/LAN(optional) |
|||
|
General Data |
||||
|
Operating Temperature Range |
-40 to +60℃, >45℃ Derating |
|||
|
Permissible Ambient Humidity |
0~100% |
|||
|
Permissible Altitude |
2000m |
|||
|
Noise |
<45 |
|||
|
Ingress Protection(IP) Rating |
IP 65 |
|||
|
Inverter Topology |
Non-Isolated |
|||
|
Over Voltage Category |
OVC II(DC),OVC IV(AC) |
|||
|
Cabinet size(W*H*D)[mm] |
420×670×233(Excluding connectors and brackets) |
|||
|
Weight[kg] |
35.6 |
|||
|
Warranty |
5 Years/10 Years |
|||
|
The Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
||||
|
Type Of Cooling |
Intelligent air cooling |
|||
|
Grid Regulation |
VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, |
|||
|
G98, G99, C10-11, UNE217002, NBR16149/NBR16150 |
||||
|
Safety EMC/Standard |
IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
|||
Core Technical Highlights
3 MPPTs (26A/string) natively support modern 182mm/210mm ultra-high-power PV modules.
Delivers 200% peak output (24,000W) for 10 seconds to easily start heavy inductive loads (HVAC, pumps).
Low-voltage (40-60V) system with adaptive BMS matching for tier-1 lithium and lead-acid brands.
Supports up to 16 units in parallel (up to 192kW) for both on-grid and off-grid configurations.
Dedicated diesel generator port with automatic dry-contact triggering for 24/7 energy assurance.
Application Boundary
Suitable for:
Residential solar energy storage systems
Small commercial buildings
Weak grid or unstable grid regions
Installation & Installer-Friendly Benefits
Compact & Lightweight Design
35.6 kg wall-mounted structure designed for standard two-person installation in residential and small commercial projects.
Standardized Electrical Interfaces
Pre-defined PV, battery, and AC terminals reduce wiring complexity and minimize installation errors.
Remote Commissioning Support
Supports remote configuration and firmware updates, reducing onsite troubleshooting and maintenance visits.
Grid Compliance Notes
Grid Compatibility
The inverter supports multiple international grid standards including:
VDE4105, IEC61727/62116, AS4777.2, EN50549-1, G98/G99, CEI 0-21
Compliance may vary depending on final installation site and local certification requirements.
Factory & Supply Security
Quality Control: ISO9001/14001 factory. Every 12kW unit undergoes a 100% full-load aging test for≥ 4 hours. Defect rate under 0.2%.
Premium Components: Configured with Tier-1 internal components (Infineon/STMicroelectronics IGBTs) for a 15+ year design life.
B2B Customization: Flexible OEM/ODM support including customized logos, localized firmware, and private-label monitoring APPs.
FAQ
Hot Tags: 12kw solar hybrid inverter, China 12kw solar hybrid inverter manufacturers, suppliers, factory
| Model | SUN-7.6K-SG02LP1-EU-AM2 | SUN-8K-SG02LP1-EU-AM2 | SUN-10K-SG02LP1-EU-AM3 | SUN-12K-SG02LP1-EU-AM3 |
| Battery Input Data | ||||
| Battery Type | Lead-acid or Lithium-ion | |||
| Battery Voltage Range(V) | 40-60 | |||
| Max.Charging Current(A) | 190 | 190 | 220 | 250 |
| Max.Discharging Current(A) | 190 | 190 | 220 | 250 |
| Charging Strategy for Li-ion Battery | Self-adaption to BMS | |||
| Number of battery input | 1 | |||
| PV String Input Data | ||||
| Max. PV Access Power (W) | 15200 | 16000 | 20000 | 24000 |
| Max DC Input Power(W) | 12160 | 12800 | 16000 | 19200 |
| Max DC Input Voltage(V) | 500 | |||
| Start-up Voltage(V) | 125 | |||
| MPPT Voltage Range(V) | 150-425 | |||
| Rated DC Input Voltage(V) | 370 | |||
| Max. Operating PV Input Current (A) | 26+26 | 26+26+26 | ||
| Max. Input Short-Circuit Current (A) | 44+44 | 44+44+44 | ||
| No.of MPP Trackers/No.of String Per MPP Tracker | 2/2+2 | 3/2+2+2 | ||
| AC Input/Output Data | ||||
| Rated AC Input/Output Active Power(W) | 7600 | 8000 | 10000 | 12000 |
| Max AC Input/Output Apparent Power (VA) | 8360 | 8800 | 11000 | 13200 |
| Peak Power (off-grid)(W) | 2 times of rated power,10s | |||
| Rated AC Input/Output Current(A) | 34.6/33.1 | 36.4/34.8 | 45.5/43.5 | 54.6/52.2 |
| Max AC Input/Output Current(A) | 34.6/33.1 | 36.4/34.8 | 45.5/43.5 | 54.6/52.2 |
| Max Continuous AC Passthrough (grid to load)(A) | 50 | 60 | ||
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |||
| Rated Input/Output Voltage/Range (V) | 220/230 0.85Un-1.1Un | |||
| Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | |||
| Grid Connection Form | L+N+PE | |||
| Total Current Harmonic Distortion THDi | <3% (of nominal power) | |||
| DC Injection Current | <0.5%ln | |||
| Efficiency | ||||
| Max Efficiency | 97.60% | |||
| Euro Efficiency | 96.50% | |||
| MPPT Efficiency | >99% | |||
| Equipment Protection | ||||
| Integrated | DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, | |||
| AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, | ||||
| Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), | ||||
| Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, | ||||
| DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level | ||||
| Surge Protection Level | TYPE II(DC),TYPE II(AC) | |||
| Interface | ||||
| Communication Interface | RS485/RS232/CAN | |||
| Monitor Mode | GPRS/WIFI/Bluetooth/4G/LAN(optional) | |||
| General Data | ||||
| Operating Temperature Range | -40 to +60℃, >45℃ Derating | |||
| Permissible Ambient Humidity | 0~100% | |||
| Permissible Altitude | 2000m | |||
| Noise | <45 | |||
| Ingress Protection(IP) Rating | IP 65 | |||
| Inverter Topology | Non-Isolated | |||
| Over Voltage Category | OVC II(DC),OVC IV(AC) | |||
| Cabinet size(W*H*D)[mm] | 420×670×233(Excluding connectors and brackets) | |||
| Weight[kg] | 35.6 | |||
| Warranty | 5 Years/10 Years | |||
| the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | ||||
| Type Of Cooling | Intelligent air cooling | |||
| Grid Regulation | VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, | |||
| G98, G99, C10-11, UNE217002, NBR16149/NBR16150 | ||||
| Safety EMC/Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | |||