5-12KW Hybrid Inverter

5-12KW Hybrid Inverter
Product Introduction:
The 5-12KW Hybrid Inverter is designed for solar + battery energy storage applications requiring stable power conversion, flexible operating modes, and reliable backup power support. Suitable for residential ESS systems, hybrid solar projects, and small commercial energy storage installations. Suitable for residential ESS systems, hybrid solar projects, and small commercial energy storage installations.
Send Inquiry
Description
Technical Parameters

Product Overview

 

The 5-12KW Hybrid Inverter is designed for solar + battery energy storage applications requiring stable power conversion, flexible operating modes, and reliable backup power support.

Suitable for residential ESS systems, hybrid solar projects, and small commercial energy storage installations.

 

Model

SUN-5K-SG04LP3-EU

SUN-6K-SG04LP3-EU

SUN-8K-SG04LP3-EU

SUN-10K-SG04LP3-EU

SUN-12K-SG04LP3-EU

Battery Input Data

Battery Type

Lead-acid or Lithium-ion

Battery Voltage Range(V)

40-60

Max.Charging Current(A)

120

150

190

210

240

Max.Discharging Current(A)

120

150

190

210

240

Charging Strategy for Li-ion Battery

Self-adaption to BMS

Number of battery input

1

PV String Input Data

Max. Recommended PV Input Power

10000

12000

16000

20000

24000

Max PV Input Power(W)

6500

7800

10400

13000

15600

MaxPV Input Voltage(V)

800

Start-up Voltage(V)

160

MPPT Voltage Range(V)

200-650

Rated PV Input Voltage(V)

550

Max. Operating PV Input Current (A)

13+13

26+13

Max. Input Short-Circuit Current (A)

17+17

34+17

No.of MPP Trackers/No.of String Per MPP Tracker

2/1+1

2/2+1

AC Input/Output Data

Rated AC Input/Output Active Power(W)

5000

6000

8000

10000

12000

Max AC Input/Output Apparent Power (VA)

5500

6600

8800

11000

13200

Peak Power (off-grid)(W)

2 times of rated power, 10s

Rated AC Input/Output Current(A)

7.6/7.2

9.1/8.7

12.1/11.6

15.2/14.5

18.2/17.4

Max AC Input/Output Current(A)

8.4/8

10/9.6

13.4/12.8

16.7/15.9

20/19.1

Max Continuous AC Passthrough (grid to load)(A)

45

Rated Input/Output Voltage/Range(V)

220/380V,230/400V 0.85Un-1.1Un

Grid Connection Form

3L+N+PE

Rated Input/Output Grid Frequency/Range

50/45-55, 60/55-65

Power Factor Adjustment Range

0.8 leading to 0.8 lagging

Total Current Harmonic Distortion THDi

<3% (of nominal power)

DC Injection Current

<0.5%ln

Efficiency

Max Efficiency

97.60%

Euro Efficiency

97.00%

MPPT Efficiency

>99%

Equipment Protection

Integrated

DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,

AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,

Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),

Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,

DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level

Surge Protection Level

TYPE II(DC), TYPE II(AC)

Interface

Communication Interface

RS485/RS232/CAN

Monitor Mode

GPRS/WIFI/Bluetooth/4G/LAN(optional)

General Data

Operating Temperature Range

-40 to +60℃, >45℃ Derating

Permissible Ambient Humidity

0-100%

Permissible Altitude

2000m

Noise

≤ 55 dB(A)

Ingress Protection(IP) Rating

IP 65

Inverter Topology

Non-Isolated

Over Voltage Category

OVC II(DC),OVC III(AC)

Cabinet size(W*H*D)[mm]

422×658×254(Excluding connectors and brackets)

Weight[kg]

38

Warranty

5 Years/10 Years

The Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy

Type Of Cooling

Intelligent air cooling

Grid Regulation

IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,

OVE-Richtlinie R25, G99, VDE-AR-N 4105

Safety EMC/Standard

IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

 

Key Technical Highlights

 

Supports up to 200% PV oversizing to maximize solar yield during low-irradiance periods.

 

Engineered for 40V–60V low-voltage battery banks to ensure optimal system safety.

 

Manages real-time power routing across PV, Battery, Grid, and Diesel Generator.

 

Delivers 2x rated surge power for 10 seconds to start heavy inductive loads.

 

Features an IP65 enclosure and Type II DC/AC surge protection for harsh environments.

 

Tailored B2B Solutions

 

BMS Self-Adaption: Factory-matched CAN/RS485 protocols for plug-and-play compatibility with your battery brands.

 

Global Grid Compliance: Pre-configured utility codes (VDE-AR-N 4105, G99, EN 50549, CEI 0-21) for immediate local approval.

 

OEM/ODM Customization: Laser-etched corporate logos on glass/aluminum housing and private-label monitoring app interface.

 

Factory Capacity & Quality Assurance

 

100% Automated Testing: PCBA produced on high-speed SMT lines with automated In-Circuit (ICT) and Functional (FCT) testing.

 

6+ Hour Burn-In: Every single unit undergoes 6+ hours of continuous 100% full-load testing inside aging chambers.

 

Massive Capacity: ISO9001 factory delivering 30,000+ units/month to guarantee stable container-level lead times.

 

FAQ

 

Q: Is this inverter compatible with high-voltage battery systems?

A: No. This series is engineered exclusively for 40V-60V Low-Voltage (LV) battery topologies. This ensures higher safety and simplifies installation compliance.

Q: Can it run fully off-grid with a generator?

A: Yes. It supports automatic diesel generator integration via dry contacts, starting the generator automatically when solar is low and batteries are depleted.

Q: Does it support remote troubleshooting?

A: Yes. Using the external Wi-Fi/4G plug-in logger, installers can adjust parameters and flash firmware remotely, significantly reducing on-site maintenance costs.

Q: What safety and grid certifications are provided?

A: We provide full IEC/EN 62109-1/-2 safety reports, IEC/EN 61000 EMC reports, and major European grid compliance certificates (VDE, G99, etc.).

 

Hot Tags: 5-12kw hybrid inverter, China 5-12kw hybrid inverter manufacturers, suppliers, factory

Model SUN-5K-SG04LP3-EU SUN-6K-SG04LP3-EU SUN-8K-SG04LP3-EU SUN-10K-SG04LP3-EU SUN-12K-SG04LP3-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range(V) 40-60
Max.Charging Current(A) 120 150 190 210 240
Max.Discharging Current(A) 120 150 190 210 240
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of battery input 1
PV String Input Data
Max. PV Access Power (W) 10000 12000 16000 20000 24000
Max PV Input Power(W) 6500 7800 10400 13000 15600
MaxPV Input Voltage(V) 800
Start-up Voltage(V) 160
MPPT Voltage Range(V) 200-650
Rated PV Input Voltage(V) 550
Max. Operating PV Input Current (A) 13+13 26+13
Max. Input Short-Circuit Current (A) 17+17 34+17
No.of MPP Trackers/No.of String Per MPP Tracker 2/1+1 2/2+1
AC Input/Output Data
Rated AC Input/Output Active Power(W) 5000 6000 8000 10000 12000
Max AC Input/Output Apparent Power (VA) 5500 6600 8800 11000 13200
Peak Power (off-grid)(W) 2 times of rated power, 10s
Rated AC Input/Output Current(A) 7.6/7.2 9.1/8.7 12.1/11.6 15.2/14.5 18.2/17.4
Max AC Input/Output Current(A) 8.4/8 10/9.6 13.4/12.8 16.7/15.9 20/19.1
Max Continuous AC Passthrough (grid to load)(A) 45
Rated Input/Output Voltage/Range(V) 220/380V,230/400V 0.85Un-1.1Un
Grid Connection Form 3L+N+PE
Rated Input/Output Grid Frequency/Range 50/45-55, 60/55-65
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5%ln
Efficiency
Max Efficiency 97.60%
Euro Efficiency 97.00%
MPPT Efficiency >99%
Equipment Protection
Integrated DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,
DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
Communication Interface RS485/RS232/CAN
Monitor Mode GPRS/WIFI/Bluetooth/4G/LAN(optional)
General Data
Operating Temperature Range -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
Noise ≤ 55 dB(A)
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated
Over Voltage Category OVC II(DC),OVC III(AC)
Cabinet size(W*H*D)[mm] 422×658×254(Excluding connectors and brackets)
Weight[kg] 38
Warranty 5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Type Of Cooling Intelligent air cooling
Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Send Inquiry
you dream it, we design it
If you have any questions
please contact us
contact us